160 Liter chamber

HSG Autoclave for medical waste sterilization Mobile medical waste sterilizer

The HSG medical waste autoclave is designed to service hospitals and medical centers that need to process medical waste biohazard safely on-site. Mobility in one easy to connect device that is reliable and easy to use.

Prevacuum Air Sterilization ensures all air that leaves the chamber prior to sterilization is treated as highly infectious and passes through a stringent biological decontamination system that renders the air sterile.

The HSG autoclave comes standard with a full temperature range and a working pressure that meets AMSE and PED requirements.

Explore this product
Powerful, reliable and customizable
The HSG medical waste autoclave provides many advantages for on-site medical waste treatment and off-site disposal of medical waste.

Cost-Effective
• Easy on-site installation removes need to transport waste to an external treatment facility
• Cost reduction in treatment and management of potentially infectious waste
• Reduced liability for waste producer due to no off-site treatment processing
• Relatively modest price and operating cost allows for quicker cost recovery

Flexible PT100 for Liquid Loads
• When treating blood, urine and other liquid medical waste a flexible PT100 placed in liquid waste load ensures sterilization at an effective sterilization temperature.
Safe Landfill Disposal
Sterilized medical waste which has been processed to remove sharps is simple to dispose in a municipal landfill
Fast cooling for fast cycles
Built-in fast cooling reduces cycle processing times enabling higher cycle rates and empowering you to sterilize medical waste without delays.
Easy to move and install
HSG is mounted on swivel wheels for easy mobility and has flexible piping for easy connection to water and drain utilities.
Environmentally Safe
• Chemical-free process
• No radiation
• Clean and environmentally safe technology
Colour graphical display
The colorful display gives you an easy-to-read overview of real-time chamber values, as well as temperature and pressure trend graphs.
Stainless Steel Piping
Piping is made of top-quality stainless steel to avoid corrosion and contamination of the sterilized loads
An optimized program for every load
HSG autoclaves include 5 fixed sterilization programs, 2 test programs and 22 customizable sterilization programs.
Your data, where you need it
The HSG medical waste autoclave gives you easy access to its cycle data. Via USB, Ethernet or printer.
Multi-Colour Display for HSG Autoclave Sterilizer
Your data, where you need it
The HSG medical waste autoclave gives you easy access to its cycle data. Via USB, Ethernet or printer.

Multi-color display store the last 200 cycles in built-in memory

Multiple access levels and user passwords for added security

Diagnostic In/Out test enables checking each system component separately

USB port got USB data storage/transfer, Ethernet and Internal battery backup

Optional remote monitoring via R.PC.R. software

Multilingual interface (26 languages)

Technical specifications
The HSG autoclave sterilizer is available manual hinged door(s).

Dimensions (W x H x D)

857mm x 1660mm x 1286mm

Chamber Dimensions (Ø x D)

500mm x 750mm

Chamber Volume

160 Liters

Electrical Supply

Three phase or one phase electrical power supply is available with many different voltages

Steam Generator Power

9 kW / 18 kW

Air filter sterilization

• 0.2 μm Biological filter • Filter is sterilized in-place during sterilization cycle

Standards and directives

(a partial list)
Directives, Guidelines & Technical Standards
Company standards and legislation
ISO 13485:2016 “Quality Management System” – “Medical devices”
Medical Device Regulation 2017/745 as amended by 2001/83/EC
Medical Device directive (MDD) 93/42/EEC
Medical Device Single Audit Program- companion document (MDSAP)
ISO 9001: 2015 “Quality Management System”
ISO 14001:2015 environmental management system
2012/19/EU WEEE and EU 2017/2102 Restriction of the use of certain hazardous substances (RoHS Directive)
Tuttnauer pressure vessels are both ASME and PED certified. All ASME certified vessels are inspected by an independent authorized ASME inspector.
Product Standards
Pressure Vessel- ASME Code section I and section VIII. Div.I
Pressure Vessel- PED 2014/68/EU
Pressure Vessel- Chinese Regulations- Special Equipment Licensing Office
EN 285 “Large steam sterilizer"
ANSI/AAMI - ST8 Hospital Steam Sterilizers
ANSI/AAMI – ST55 Tabletop steam sterilizer
IEC 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements EN
IEC 61010-2-040: Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-040: Requirements for sterilizers and washer-disinfectors used to treat medical materials
EN 61326-1 EMC Requirements for Electrical Equipment
IEC 62304: Medical Device Software – Software life cycle processes
Loading Cart for Waste Transfer
A specialized loading cart for safely transferring medical waste is available.
Loading Cart for Waste Transfer
A specialized loading cart for safely transferring medical waste is available.

The bottom shelf has no holes to prevent liquid from leaking out of the cart

The bottom shelf has a drain to enable collection of any liquid waste into a container

All the shelves have a barrier around their perimeter to prevent waste from falling off the cart

Need more Information?
Brochure
Download the brochure and learn more about this autoclaves capabilities
Need help choosing?
Ready to place your order? We are here to assist you with any questions you may have.
Was this helpful?
Sorry about that
How can we improve it?
Thanks for your feedback!