• Advanced F₀ minimizes liquid exposed to heat, and reduces energy consumption
• Disinfection/Isothermal Cycle (70-95°C)
• Advanced options for stringent biotechnology requirements
• Separate jacket and chamber connections option for fast sterilization and superior temperature control
Fast Cooling
Accelerated cooling technology increases the amount of cycles per day and protects the load by minimizing its exposure to high temperatures.
Rapid cooling safely reduces cooling time by as much as 75% without compromising the load. After sterilization is completed, air is passed through a microbiological filter.
Chamber temperature is decreased while pressure reduces and steam and condensate are drained.
The jacket is filled with purified cold water to help cool down the chamber to a safe temperature.
When the liquid’s temperature reaches the final set temperature, the cooling stage is complete.
Advanced Sterilization Cycles
F₀ Cycle – An additional challenge with liquid sterilization is the need to prevent extended exposure of liquid media to high temperatures which may harm the quality of the liquid media. The advanced F₀ optional feature assists in minimizing the time liquids are exposed to high temperatures during
sterilization thereby protecting liquid media, saving your laboratory time and reducing energy consumption.
Disinfection/Isothermal Cycle (70-95°C) – A flexible low Temperature cycle enables disinfection (“low” temperature
isothermal).
Air Removal, Vacuum Cycles
The autoclave’s vacuum pump efficiently removes residual air prior to sterilization, enabling effective penetration of steam.
The post-vacuum drying phase, at the end of the sterilization cycle, ensures complete drying of porous loads and hollow instruments. This guarantees that even the most difficult loads will easily reach sterility assurance levels.
Advanced Options
Advanced options allow for sanitary conditions to be maintained and satisfy stringent requirements for the biotechnology and food processing industries.
Separate Jacket and Chamber Connections enable reaching sterilization temperatures faster and improve temperature control. Often used for sterilizing liquids and vital when working with clean steam.
7" multi-color touch screen panels store the last 200 cycles in built-in memory
Multiple access levels and user passwords for added security
Diagnostic In/Out test enables checking each system component separately
USB Ports, Ethernet and Internal battery backup
Optional features include isothermal cycle for low temperature disinfection, software control and remote monitoring via R.PC.R. software
Two PT100 sensors according to EN 61010-1, EN 61010-2-040
PID (Proportional Integral Differential) pressure control
Optional Control Features
• 10” Multi-color touch screen
• Up to 8 different barcode readers
• Fo software control
• 21 CFR part 11
Dimensions (W x H x D)
610mm x 610mm x 1215mm
Chamber Volume
450 Liter
Electrical Supply
Three phase or one phase electrical power supply is available
Door Configuration
66120-1V sterilizer with one vertical sliding door.
66120-2V sterilizer with two vertical sliding doors.
Standards and directives