160 Liter chamber

5075GS Autoclave Cost effective, hospital grade autoclave

The 5075GS autoclave is designed for Hospital CSSD, OR, and Medical Centers with limited budgets that need reliable sterile processing using hospital grade autoclaves. The rounded chamber and coiled jacket reduce the manufacturing costs which allow for more affordable autoclaves.

  • Pass-through between sterile & non-sterile areas
  • Single and double doors, automatic locking
  • Sterilization of wrapped and unwrapped equipment
  • Cost-effective
Explore this product
Narrow, convenient and affordable
Packed with all the features and reliability of a large capacity autoclave at a fraction of the size and cost.
5075GS Autoclave
More Affordable
Rounded chamber and coiled jacket reduce the manufacturing cost of the autoclave for facilities with limited budget
Simplified Design
Simplified design allows for low maintenance while maintaining hospital grade performance
Narrow Design
Designed for limited space. Narrow 84 cm width allow for more autoclaves in a limited area, reducing downtime risk
Convenient
1 Wall pass-through installation between non-sterilie and sterile rooms. Additional service area not required.
Stainless Steel Piping
Piping is made of top-quality stainless steel to avoid corrosion and contamination of the sterilized loads
Low Maintenance
Less parts and reduced complexity result in low long-term maintenance costs
An optimized program for every load
The 5075GS comes with 8 pre-set and 20 customizable cycle programs, as well as 2 standard diagnostic tests.
Preset Cycles

Load Type

Temperature

Sterlization Time

Drying Time

Cycle Time*

Unwrapped instruments

134 °C

4 min.

1 min.

24 min.

Wrapped instruments

134 °C

7 min.

20 min.

37 min.

Unwrapped delicate instruments

121 °C

20 min.

1 min.

36 min.

Wrapped delicate instruments

121 °C

20 min.

20 min.

50 min.

Prion instruments

134 °C

18 min.

20 min.

50 min.

Leak Test

-

-

-

31 min.

Bowie & Dick Test

134 °C

3.5 min.

2 min.

21 min.

* Cycle times based on a 15kg load for 5075GS, excluding drying, based on warm chamber, and may change according to load. Bowie & Dick Test is suitable for Helix test device. Leak Test checks that the chamber under vacuum does not leak.

Test Cycle

Verify proper air removal from the autoclave chamber.

Leak Test Cycle

Verify the integrity of the pressure vessel and its plumbing on a daily or weekly basis.

Your data, where you need it
El 5075GS le brinda fácil acceso a sus datos de ciclo. Por medio de USB, Ethernet o la impresora.
Your data, where you need it
El 5075GS le brinda fácil acceso a sus datos de ciclo. Por medio de USB, Ethernet o la impresora.

7” Multi-color touch screen panel on both sides

Multiple access levels for added security

Graphical display of Temperature and Pressure trend graph

Stores the last 200 cycles in built-in memory

USB and Ethernet Ports

Multilingual interface (26 languages)

5075GS Autoclave
Technical specifications

Chamber Dimensions (Ø x L)

500mm x 810mm

Chamber Volume

160 Liters

Overall Dimensions (WxHxD) 1 Door

837mm x 2027mm x 1155mm

Overall Dimensions (WxHxD) 2 Door

837mm x 2027mm x 1010mm

Basket Capacity

1 StU, 2 ISO

Tray Dimensions (WxHxD)

1 Door: 310mm x 21mm x 773mm, 2 Door: 471mm x 25mm x 675mm

Voltage & Frequency

3 phases (option 1 phase), 208V, 230V, 400V, 50-60 Hz

Steam Generator

18 kW

Standards and directives

(a partial list)
Standards
EN285:2006+A2:2009 for large autoclaves
ANSI/AAMI – ST 8: 2008 – Hospital Sterilizers
EN 61010-1: 2010 Safety Requirements for measurement control and laboratory use
EN 61326-1: 2006 Electrical Equipment for EMC Requirements
EN 61010-2-40:2005 Safety requirements for sterilizers used to treat medical equipment
EN 17665-1:2006 Sterilization of Health Care Products - Moist Heat
Pressure vessel
All pressure vessels and boilers are certified according to ASME code, section I and section VIII, Div. I and PED 97/23/EC - Directive for pressure equipment
Quality Standards
• ISO 9001:2008 Quality Control Systems
• EN ISO 13485:2012 Quality Control Systems – Medical Equipment
Directives
• MDD 93/42/EEC as amended by Directive 2007/47/EEC
• 2002/96/EC WEEE and 2002/95/EC RoHS
Need more Information?
Brochure
Download the brochure and learn more about this autoclaves capabilities
Need help choosing?
Ready to place your order? We are here to assist you with any questions you may have.
Was this helpful?
Sorry about that
How can we improve it?
Thanks for your feedback!