The 5075GS autoclave is designed for Hospital CSSD, OR, and Medical Centers with limited budgets that need reliable sterile processing using hospital grade autoclaves. The rounded chamber and coiled jacket reduce the manufacturing costs which allow for more affordable autoclaves.
Packed with all the features and reliability of a large capacity autoclave at a fraction of the size and cost.
More Affordable
Rounded chamber and coiled jacket reduce the manufacturing cost of the autoclave for facilities with limited budget
Simplified Design
Simplified design allows for low maintenance while maintaining hospital grade performance
Narrow Design
Designed for limited space. Narrow 84 cm width allow for more autoclaves in a limited area, reducing downtime risk
Convenient
1 Wall pass-through installation between non-sterilie and sterile rooms. Additional service area not required.
Stainless Steel Piping
Piping is made of top-quality stainless steel to avoid corrosion and contamination of the sterilized loads
Low Maintenance
Less parts and reduced complexity result in low long-term maintenance costs
An optimized program for every load
The 5075GS comes with 8 pre-set and 20 customizable cycle programs, as well as 2 standard diagnostic tests.
Preset Cycles
Load Type
Temperature
Sterlization Time
Drying Time
Cycle Time*
Unwrapped instruments
134 °C
4 min.
1 min.
24 min.
Wrapped instruments
134 °C
7 min.
20 min.
37 min.
Unwrapped delicate instruments
121 °C
20 min.
1 min.
36 min.
Wrapped delicate instruments
121 °C
20 min.
20 min.
50 min.
Prion instruments
134 °C
18 min.
20 min.
50 min.
Leak Test
-
-
-
31 min.
Bowie & Dick Test
134 °C
3.5 min.
2 min.
21 min.
* Cycle times based on a 15kg load for 5075GS, excluding drying, based on warm chamber, and may change according to load. Bowie & Dick Test is suitable for Helix test device. Leak Test checks that the chamber under vacuum does not leak.
Test Cycle
Verify proper air removal from the autoclave chamber.
Leak Test Cycle
Verify the integrity of the pressure vessel and its plumbing on a daily or weekly basis.
Your data, where you need it
El 5075GS le brinda fácil acceso a sus datos de ciclo. Por medio de USB, Ethernet o la impresora.
Your data, where you need it
El 5075GS le brinda fácil acceso a sus datos de ciclo. Por medio de USB, Ethernet o la impresora.
7” Multi-color touch screen panel on both sides
Multiple access levels for added security
Graphical display of Temperature and Pressure trend graph
Stores the last 200 cycles in built-in memory
USB and Ethernet Ports
Multilingual interface (26 languages)
Technical specifications
Chamber Dimensions (Ø x L)
500mm x 810mm
Chamber Volume
160 Liters
Overall Dimensions (WxHxD) 1 Door
837mm x 2027mm x 1155mm
Overall Dimensions (WxHxD) 2 Door
837mm x 2027mm x 1010mm
Basket Capacity
1 StU,
2 ISO
Tray Dimensions (WxHxD)
1 Door: 310mm x 21mm x 773mm, 2 Door: 471mm x 25mm x 675mm
EN 61010-1: 2010 Safety Requirements for measurement control and laboratory use
EN 61326-1: 2006 Electrical Equipment for EMC Requirements
EN 61010-2-40:2005 Safety requirements for sterilizers used to treat medical equipment
EN 17665-1:2006 Sterilization of Health Care Products - Moist Heat
Pressure vessel
All pressure vessels and boilers are certified according to ASME code, section I and section VIII, Div. I and PED 97/23/EC - Directive for pressure equipment
Quality Standards
• ISO 9001:2008 Quality Control Systems
• EN ISO 13485:2012 Quality Control Systems – Medical Equipment
Directives
• MDD 93/42/EEC as amended by Directive 2007/47/EEC
• 2002/96/EC WEEE and 2002/95/EC RoHS
Need more Information?
Brochure
Download the brochure and learn more about this autoclaves capabilities